| No. | Property | Reference Standard | Unit | Test Value | Remarks |
|---|
| 1 | Flexural Strength | ISO 14125 | MPa | 1440.21 | |
| 2 | Tensile Strength | ISO 527-4 | MPa | 1149.23 | |
| 3 | Corner Code Frame Coordination Bearing Capacity | IEC 62790 | - | Test Passed | |
| 4 | Straightness | YS/T 773:2020 | mm/m | 0.40 | |
| 5 | Flame Retardancy | IEC 60695-11-10 | - | V-0 | |
| 6 | Barcol Hardness | ASTM D2583-95 | Hba | 65 | |
| 7 | Damp Heat Test DH1000 | IEC 61215-2 | - | Test Passed | TÜV actual dual 85 conditions, tensile strength retained 100%, cross-section shear retained 86%, etc. |
| 8 | High-Low Temp Cycle TC200 | IEC 61215-2 | - | Test Passed | TÜV actual TC200, tensile strength 100%, cross-section shear 100%, compressive shear 100%, etc. |
| 9 | UV Resistance UV2000 | IEC 62790 | - | Test Passed | TÜV actual 120kWh/m², tensile strength retained 100%, cross-section shear retained 100%, etc. |
| 10 | TC50+HF10 | IEC 61215-2 | - | Test Passed | After TÜV actual test, tensile strength retained 93%, cross-section shear retained 91%, etc. |
| 11 | Ammonia Resistance | IEC 62716 | - | Test Passed | TÜV actual ammonia resistance, tensile strength retained 99.9%, cross-section shear retained 100%, etc. |
| 12 | Salt Spray Test | IEC 60068-2-52 | - | Test Passed | TÜV actual salt spray resistance level 8, tensile strength retained 100%, cross-section shear retained 100%, etc. |
| 13 | Sulfur Dioxide Resistance | ISO 6988 | - | Test Passed | After TÜV actual test, tensile strength retained 99%, cross-section shear retained 97%, etc. |